Gas Burner Avanzini Drago P1 Plus

Indications for the position of the Drago burner inlet hole in the hotplate of the wood oven, view from above. The hole may be drilled either on the right or on the left.

The gas supply must be delivered through a galvanized pipe Ø 1/2” or equivalent copper pipe, located at the burner inlet hole, 5 cm (2”) from the ground. Install the gas ONOFF tap in a suitable position upstream. Remember to clean the flue to free it of any ash that might have been produced by the combustion of the wood.

This model have manual thermostat.

Description

HEATING CAPACITY GAS PRESSURE GAS VOLUME GAS CONNECTION WEIGHT
Min Kw Max Kw Min Kcal/h Max Kcal/h Min BTU Max BTU Min mbar Max mbar Min Nm3/h Max Nm3/h Inches in Kg
P1 PLUS 11 24 9,400 20,640 37,500 81,900 1,5 50 1,16 2,54 1/2 4